Foundation–soil contact grouting

Strengthening the base without changing the foundation design: fine cement mortar is injected under pressure through holes in the body of the foundation. It fills voids and washout zones under the sole - uneven precipitation stops, bearing capacity increases.

View interactive diagram →
01

Where it is used

  • — Progressive uneven precipitation
  • — Consequences of foundation erosion by water
  • — Preparation for superstructure and reconstruction
  • — Restoring contact after vibrations
  • — Local subsidence of strip and column foundations
02

Specifications

Boreholes
Ø 25–50 mm, penetration into the ground below the base 0.3–0.8 m
Hole pitch
0.5–1.5 m
Solution
microcement, W/C ≈ 0.6–1.0
Pressure
up to 0.3–0.5 MPa, cyclically
Hardening
7–14 days
03

Work stages

  1. 01 Inspection: cracks, subsidence, foundation material, geodetic monitoring
  2. 02 Drilling holes and installing injection tubes with a packer
  3. 03 Injection until a sharp increase in pressure or calculated volume
  4. 04 Strengthening and geodetic stabilization control
04

Standards and regulations

  • — SP 22.13330 “Foundations of buildings and structures”
  • — SP 45.13330 “Earth structures, foundations and foundations”
  • — SP 291.1325800.2017 “Soil-cement reinforced structures”
  • — GOST R 59538-2021 - cement-based injection mortars
  • — GOST 31108-2016 “General construction cements”