Home / Ground improvement / Tube-à-manchette grouting Tube-à-manchette grouting Interval injection of solution into the soil through a pipe with cuffs that open only at a given pressure. You can re-treat the interval, control the area where the solution spreads and prevent it from reaching the surface.
View interactive diagram → 01 Where it is used — Strengthening the foundations of existing buildings — Cramped construction conditions — Emergency leaks and quicksand — Waterproofing, problematic soils 02 Specifications Wells Ø 40–100 mm Cuff pitch 0.3–0.5 m Discharge pressure 0.3–5 MPa Crude plugging hardens in 1–3 days Durability gain setting 2–3 days, design ≈ 28 days 03 Work sequence 01 Well drilling; in loose soils - with casing pipes 02 Installation of a collar column and plugging of the annulus 03 Bottom-up injection with a double-sleeve packer until “failure” or design volume 04 Hardening: zones of adjacent intervals close into a single massif 04 Standards and regulations — SP 291.1325800.2017 “Soil-cement reinforced structures” — SP 22.13330 “Foundations of buildings and structures” — SP 45.13330 “Earth structures, foundations and foundations” — GOST R 59538-2021, GOST R 70696-2023 - cement-based injection mortars — GOST 31108-2016 “General construction cements” — GOST 23732 - water for concrete and mortars — STO NOSTROY 2.3.18-2011 - soil strengthening using injection methods